Digital Video Recorder
V1.0
79
INPUTS/OUTPUTS
Alarm Input 8 or 16 terminal, programmable as NC or NO, 2.4V (NC) or 0.3V (NO) threshold, 5VDC
Alarm Output 4 relay output, programmable as NC or NO, 2A@125VAC, 1A@30VDC
Alarm Reset Input 1 TTL, terminal block
Internal Buzzer 80dB at 10cm
Network Connectivity 10Mbps/1Gbps Ethernet (RJ-45)
Audio Input RCA Input: 16 Line In
Audio Output RCA Output: 1, Line Out
Text Input POS Interface, ATM Interface
CONNECTORS
Video Input Composite: 8 or 16 BNC
Video Loop Composite: 8 or 16 BNC (Auto Terminating)
Monitor Output
HDMI: 1 HDMI
Composite: 1 BNC
VGA: 1 VGA
SPOT (Composite): 1 BNC
Audio In 16 RCA connector
Audio Out 1 RCA connector
Alarm Input/Output Terminal Blocks
Ethernet Port 2 RJ-45
eSATA Port eSATA
RS232C Serial Port DB9 (P)
RS485 Serial Port Two-connector terminal block
IR Port 1 Remote Control
USB Port 2 (USB 2.0)
STORAGE
Primary Storage SATA hard disk drive (up to 5) (up to 4 with an eSATA hard disk drive)
Secondary Storage*
eSATA hard disk drive (RAID)
iSCSI hard disk drive (RAID)
Built-in DVD RW drive
USB hard disk drive or flash drive
* When installing an internal DVD RW drive, connect the SATA I/O cable to the SATA ODD socket.
GENERAL
Dimensions (W x H x D)
16.9" x 3.5" x 19.3" (430mm x 88mm x 490mm)
Unit Weight 22.9 lbs. (10.4kg)
Shipping Weight 30.9 lbs. (14.0kg)
Shipping Dimensions
(W x H x D)
26.9" x 10.7" x 21.2" (683mm x 271mm x 538mm)
Operating Temperature 41°F to 104°F (5°C to 40°C)
Operating Humidity 0% to 90%
Power 100 to 240 VAC, 2.0 – 1.0 A, 50/60Hz
Power Consumption Max. 100W
Approvals FCC, UL**, CB, CE
** CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. This equipment
is indoor use and all the communication wiring are limited to inside of the building.
Specifications are subject to change without notice.